Overview
What is a UR connector?
A UR connector is a red translucent gel-filled dual-IDC splice connector with a PC / Polycarbonate body, used to join two or three supported solid copper telephone wires without stripping the insulation. It supports 0.4-0.9 mm / 26-19 AWG wire and a maximum insulation O.D. of 1.52 mm / 0.060 in. During crimping, the IDC contacts cut through the wire insulation while the gel helps reduce moisture exposure around the splice area.
Specifications
UR connector technical data
These are the confirmed technical details for Mintel UR connectors used in supported copper telephone wire repair and tap splice work.
| Parameter | Value |
|---|---|
| Connector type | Gel-filled IDC splice connector |
| Wire count | 2-wire or 3-wire splice |
| Wire range | 0.4-0.9 mm / 26-19 AWG solid copper wire |
| Maximum insulation O.D. | 1.52 mm / 0.060 in |
| Body material | PC / Polycarbonate |
| Contact material | Tin-plated phosphor-bronze IDC contact |
| Contact format | Dual IDC contact |
| Sealant | Gel-filled |
| Color | Red / translucent |
| Wire preparation | No stripping required for supported wires |
| Typical use | Copper telephone wire repair, 2-wire or 3-wire splice work, tap splice requirements |
| Selection note | For yellow 2-wire splice requirements in the same 0.4-0.9 mm wire range, review the UY2 connector. For red 2-wire or 3-wire splice requirements with a larger maximum insulation outside diameter, review the UR2 connector. |
Installation
UR connector installation steps
Insert two or three supported solid copper wires fully into the connector ports. No wire stripping, soldering, heat shrink, or tape is required for supported wire sizes.
- Prepare the wire ends: cut the solid copper wires with clean, square ends. Do not strip the insulation.
- Insert the wires: push each wire fully into the UR connector ports until they bottom out.
- Confirm wire count: use UR for supported 2-wire or 3-wire splice requirements.
- Crimp the connector: use a compatible parallel-action crimping tool to fully crimp the red cap.
- Check the splice: confirm that the cap is closed and all wires are held firmly.
Model comparison
UR compared with UY2 and UR2 connectors
Buyers often compare UR with UY2 and UR2 because the three models cover the most common choice points around wire count, connector color, and insulation diameter. UR and UY2 share the same 0.4-0.9 mm wire range, but UR is red and supports 2-wire or 3-wire splice work. UR and UR2 are both red connectors for 2-wire or 3-wire requirements, but UR2 supports a larger maximum insulation outside diameter.
- Choose UR: red 2-wire or 3-wire splice where the maximum insulation O.D. is up to 1.52 mm / 0.060 in.
- Choose UY2: yellow 2-wire splice when the project requires a yellow connector format.
- Choose UR2: red 2-wire or 3-wire splice when the insulation O.D. requirement is up to 2.08 mm / 0.082 in.
| Parameter | UR | UY2 | UR2 |
|---|---|---|---|
| Color | Red | Yellow | Red |
| Wire count | 2-wire or 3-wire | 2-wire | 2-wire or 3-wire |
| Wire range | 0.4-0.9 mm / 26-19 AWG | 0.4-0.9 mm / 26-19 AWG | 0.4-0.9 mm / 26-19 AWG |
| Max insulation O.D. | 1.52 mm / 0.060 in | 2.08 mm | 2.08 mm / 0.082 in |
| Blade/contact | Dual IDC contact | Single IDC contact | Dual IDC contact |
| Typical use | Red connector for repair and tap splice work | Yellow 2-wire splice for larger wire or insulation diameter requirements | Red connector for 2-wire or 3-wire requirements with larger insulation diameter |
| Page | This page | /uy2-connector/ | /ur2-connector/ |
Selection guide
When to choose UR
Choose UR when the project requires a red translucent gel-filled dual-IDC connector with a PC / Polycarbonate body for supported 2-wire or 3-wire copper telephone wire splice work, with maximum insulation O.D. within 1.52 mm / 0.060 in.
- The wire size is within 0.4-0.9 mm / 26-19 AWG.
- The maximum insulation outside diameter requirement is up to 1.52 mm / 0.060 in.
- The splice requires two or three supported solid copper wires.
- The buyer specification, drawing, or inventory code calls for UR.
- The project requires a red connector for field repair or tap splice work.
- UR is already the model used in the existing telecom maintenance system.
Applications
Where UR connectors are used
Mintel UR connectors are used in copper telecom and qualified low-voltage wiring applications where a red gel-filled IDC splice is required for supported wire sizes.
- Copper telephone cable repair
- 2-wire or 3-wire splice work
- Tap splice and branch splice applications
- Field maintenance in copper telecom networks
- Outdoor or humid splice points inside suitable closures
- Distributor inventory for red connector demand
- Selected low-voltage alarm or sensor wiring when wire size and application match the UR specification
Factory supply
Factory-direct UR connector supply
Mintel was founded in 2012, building on family copper telecom connector manufacturing know-how since 1986. The company manufactures gel-filled IDC splice connectors and related copper wire connector products from a single factory source for telecom, distributor, OEM, and selected low-voltage buyers.
- Factory-direct communication for model selection and quotation
- Bulk supply and distributor order support
- Neutral packaging for standard orders
- OEM packaging support by project discussion
- Model comparison support across UY, UY2, UR, UR2, and UB2A
- RoHS and REACH documentation can be arranged for qualified orders
FAQ
Buyer questions
What is a UR connector?
A UR connector, also called a red button connector, is a red gel-filled IDC splice connector used to join two or three supported solid copper telephone wires without stripping the insulation.
What wire sizes does the UR connector support?
The UR connector supports 0.4-0.9 mm / 26-19 AWG solid copper wire, with a maximum insulation outside diameter of 1.52 mm / 0.060 in.
Is the UR connector gel-filled?
Yes. The UR connector is gel-filled to help reduce moisture exposure around the splice area in suitable telecom field environments.
Does the UR connector resist moisture?
Yes. The gel helps protect the splice from moisture when the wire and installation match the connector specifications.
Can UR connect three wires?
Yes. UR is used for supported 2-wire or 3-wire splice requirements. Buyers should confirm wire size, insulation outside diameter, and installation conditions before ordering.
Is a UR connector the same as a button connector?
Button connector is a common field name for UR-style connectors because of the red button-style cap. On this page, UR connector refers to the red gel-filled IDC splice connector used for supported 2-wire or 3-wire copper telephone wire splicing.
What is the difference between UR and UR2 connectors?
UR and UR2 are both red translucent gel-filled dual-IDC splice connectors for 2-wire or 3-wire requirements. UR has a PC / Polycarbonate body and supports maximum insulation O.D. up to 1.52 mm / 0.060 in; UR2 has a PP / Polypropylene body and supports up to 2.08 mm / 0.082 in.
What is the difference between UR and UY2 connectors?
UR is a red connector for 2-wire or 3-wire repair and tap splice work. UY2 is a yellow 2-wire connector for applications that require a yellow connector format and maximum insulation O.D. up to 2.08 mm.
How do you install a UR connector?
Insert two or three supported solid copper wires fully into the connector ports. Use a compatible parallel-action crimping tool to fully crimp the red cap. No stripping or soldering is required.
Can Mintel supply UR connectors in bulk?
Yes. Mintel supports factory-direct bulk supply, distributor orders, neutral packaging, and OEM packaging discussion for qualified B2B buyers.
Can I include UR with other connector models in one inquiry?
Yes. Buyers can include UY, UY2, UR, UR2, UB2A, and related connector requirements in one inquiry. Share model names, quantities, wire specifications, packaging needs, destination country, and documentation requirements.
Standard packaging
- Bag quantity
- 100 pcs
- Inner box quantity
- 100 pcs
- Outer carton quantity
- 10,000 pcs
- Inner box size (L × W × H)
- 6.2 × 6.2 × 5.5 cm
- Outer carton size (L × W × H)
- 33 × 26 × 31 cm
- G.W. / N.W. per outer carton
- 11 kg / 10 kg

Custom pack quantities and private label available by order.
For a quote, include the model and quantity, wire size and insulation O.D., packaging requirements, destination and any documents needed.
Have a tender specification or an existing model? Send it and we will confirm the match. For attachments, use the email link on our contact page.
Request a Quote
Copper Wire Connector Manufacturer